By: K.P. Singh

Published: Journal of Heat Transfer

Year: 1981

Abstract: Governing equations for heat transfer in a split flow heat exchanger with two tube passes are developed and solved. The expressions for the 鈥渢emperature efficiency鈥 P and 鈥淟MTD temperature correction factor鈥, F are derived. F and P values for two tube pass and four tube pass are compared over the practical range of values of thermal flow rate ratio R and reduced thermal flux, 畏 (NTU).

Citation: Singh, K. “A Comparison of Thermal Performance of Two and Four Tube Pass Designs for Split Flow Shells,鈥 Journal of Heat Transfer, Trans. of the ASME, Vol. 103, No. 1, pp 169-172, February 1981.